| RECOMMENDED
DOSAGE & ADMINISTRATIONMETHOD. |
- Injected as a single implant dose
- Can be injected immediately prior to the
normal spawning season
- Spawning of groups can be advanced and
synchronized
- Repeat injections can be given to fish
treated long before normal spawning
SEDATION FOR HANDLING
If sedation is required, use a plastic or
glass tank of sufficient size to hold the fish. Anesthetize with TMS
(Tricaine Methanesulfonate) or Aquacalm at the recommended level, being sure
to mix thoroughly BEFORE adding the fish. Always handle fish gently. Avoid
contact between the anesthetic solution and eggs or milt.
INJECTING Ovaplant
- CLEANLINESS - Ensure that all
equipment is clean and, if possible, sterilized. Wear gloves.
- INJECTION - Inject
using the supplied
injection needle and gun into the dorsal sinus. Ensure that both males
and females are injected at the same time. Inject Ovaplant
carefully, and quickly remove the needle. Gently place the fish into a
container of fresh, aerated water.
- RECOVERY-
After the fish has recovered
from sedation (5 to 10 minutes), return it to the breeding tank. More
than one fish may be induced at the same time.
|